Max.Head: <10m
Max.Capacity: 200-300 L/min
Driving Type: Motor
Impeller Number: Single-Stage Pump
Working Pressure: Middle Pressure Pump
Influent Type of Impeller: Single Suction Pump
Customization:
Gold Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
50WQ10-10-0.75(A)
Position of Pump Shaft
Vertical Pump
Pump Casing Combined
Verticaljoint Surface Pump
Mounting Height
Since Irrigation Centrifugal Pumps
Impeller
Open
Usage
Pump, Pumps, Circulating Pump, Water Treatmen, Daily Life, Agriculture, Industry
Transport Package
Fumigation Wooden Crate
Trademark
Huayang
Origin
China
HS Code
8413709190

Product Description

WQ Series Sewage Water Pump 220V For Municipal Engineering , 0.37-7.5KW

 

Introduction

WQ submersible sewage pump is developed digestion and absorption of foreign advanced technology similar products on the basis of a successful, efficient, anti-winding, non-blocking, automatic coupling, high reliability and automatic control, etc., in the carriage of solid particles and long fiber refuse , has a unique feature.

 

WQ submersible sewage pump is small, compact, high efficiency, the water level can be automatically controlled according to user requirements, with automatic protection devices and control cabinets, dual-rail system is installed automatically.

Applications

WQ submersible sewage pump is mainly used for municipal engineering, industry, hospitals, buildings, hotels, restaurants and other industries. For sludge, waste, urban sewage discharge conveyor belt and a variety of solid long fibers (including corrosive, aggressive media applications).

Features

♦18.5KW more external circulating water pump automatic cooling, to ensure the safe operation of the electric pump at the lowest level status.

♦Tt the upper end of the pump and motor oil chamber equipped with water probe for monitoring the implementation of the water pump mechanical seal, once the leak, the control system will alarm protection.

♦Vice impeller for balancing mechanical seal external pressure, prevent water from entering the oil chamber, thus extending the life of the pump.

♦Impeller design unique, large passage through the long fibers and dirt, anti-clogging, anti-winding, high flow capacity.

♦Fitted between the impeller and volute lower end of the replaceable wear sleeve to keep the pump running at optimum efficiency.

Operation Mode

♦ the motor rated voltage 380V, frequency 50HZ three-phase AC power.

♦ the transmission medium temperature does not exceed 40oC.

♦ transmission fluid medium PH value 4-10.

♦ the solid phase material transport medium volume ratio of less than 2%.

♦ the transmission medium density of less than 1.2 × 103Kg / m3


 
fault phenomenon failure cause elimination methods
  1.No power supply or one or two phase power supply is needed  
Check all phases of power supply and restore power supply
 
 
  2.Poor contact of ac contactor and burning of coil  
Repair or replace contactors
 
 
can not start 3.
The power switch is not closed, malfunction or damaged
 
 
Close the switch and replace it if the power indicator does not turn on
  4.
Thermal relay trip or damage
 
 
Check whether the motor is blocked, find out the reason and eliminate it.Manual reset is replaced if it cannot be started
  Water level is too low  
Put water in the sink
 
 
  The motor burned  
Repair or replace the motor
 
 
  1.Line is loose  
Check wiring and tighten connectors
 
 
  2.Frequency converter malfunction Check the fault content, check the cause according to the frequency converter manual, and restart after reset.Or disconnect the inverter power supply for a few seconds, the inverter fault reset before starting.
The manual is normal 3The frequency converter is damaged Repair or replace
Automatic transmission failure 4.Pressure switch damage Repair or replace
  5The pressure transmitter is damaged Repair or replace
  6.Switch failure Repair or replace
Pump non - suction pressure gauge pointer to beat violently Insufficient water supply for perfusion, air leakage at the connection between pipeline and instrument Check pipeline and bottom valve, refill water diversion. Tighten air leakage
 
The pump consumes too much power
 
 
 
Too much flow, impeller wear
 
 
Check whether the pump shaft is bent, replace the impeller, close the outlet valve to reduce the flow


1.0HP 220V Cast Iron Submersible Pump Sewage Water Pumps1.0HP 220V Cast Iron Submersible Pump Sewage Water Pumps1.0HP 220V Cast Iron Submersible Pump Sewage Water Pumps

1.0HP 220V Cast Iron Submersible Pump Sewage Water Pumps1.0HP 220V Cast Iron Submersible Pump Sewage Water Pumps1.0HP 220V Cast Iron Submersible Pump Sewage Water Pumps
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
414
Year of Establishment
2001-06-21